No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
+
  • No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
  • No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
  • No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
  • No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
  • No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms
  • No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms

No Pipe Needed HFC-227ea Fire Protection System FM200 Cabinet Fire Extinguishing 90L A/B/C Rated for Control Rooms

电话:

还在犹豫?先拿样品吧,联系我们!

查看类似产品

标签列表

  • 产品描述
  • The fire extinguishing principle of heptafluoropropane belongs to the category of chemical fire extinguishing, and its fire extinguishing mechanism is composed of the following three parts :1. Cooling the protected area; 2. Fire extinguishing agent dispersion; 3 Consume oxygen.
    The fire extinguishing agent is sprayed into the protected area in the form of liquid, and the rapid transformation of the liquid fire extinguishing agent into a gas phase needs to absorb a lot of heat, reducing the temperature around the protected area and the flame.
    The extinguishing agent is composed of large molecules, and some of the bonds in the molecules break during extinguishing the fire to absorb heat. The injection of fire extinguishing agent and the presence of flame in the protected area reduce the concentration of oxygen, thus reducing the speed of combustion.
    Working pressure
    2.5MPa(20℃)
    Ambient temperature
    0~50℃
    Electric, mechanical manual start
    DC24V
    Pneumatic, mechanical manual start
    ≤150N
     Injection time
    ≤10S
    Model number
    Storage bottle specification
    Number of bottles
    Injection duration
    (S)
    Size(mm)
    (L*W*H)
    GQQ40*2/2.5-XF
    40L




    2



    0~3
    980*450*1200
    GQQ70*2/2.5-XF
    70L
    980*450*1400
    GQQ90*2/2.5-XF
    90L
    980*450*1700
    GQQ100*2/2.5-XF
    100L
    980*450*1700
    GQQ120*2/2.5-XF
    120L
    980*450*1950
    GQQ150*2/2.5-XF
    150L

    3~5
    980*500*1950
    GQQ180*2/2.5-XF
    180L

    980*500*2100
    1. Can extinguish all kinds of fires A, B, C, and can be used safely and effectively in places with people; 2. After spraying, no traces or cleaning residues are required 3. The protected area contains valuable articles, priceless treasures, precious archives, hardware and software, etc. 4. Especially suitable for: telecommunication main control room, airport control room, bank vault, archives, library, computer room and other occasions.